鸭脖官网

Welcome to Dongguan GAODA Instrument Co., Ltd!
Your location: home page > Product line > Rubber / plastic detector >
 Small plate curing press gd-300b
  •  one

Small plate curing press gd-300b

Product specification: Small plate curing press gd-300b
This series of plate curing press is used to press all kinds of rubber model products and non model products, as well as various thermosetting plastics and foamed rubber and plastic products. It has independent power mechanism and electrical system, and adopts button centralized control. working pressure
 This series of plate curing press is used to press all kinds of rubber model products and non model products, as well as various thermosetting plastics and foamed rubber and plastic products. It has independent power mechanism and electrical system, and adopts button centralized control. working pressure
 Online consultation Online consultation

National Service Hotline: 0769-22247727

Product features
 
1、 Overview
 
This series of plate curing press is used to press all kinds of rubber model products and non model products, as well as various thermosetting plastics and foamed rubber and plastic products. It has independent power mechanism and electrical system, and adopts button centralized control. The working pressure and heating temperature can be adjusted in a certain range. Two types of semi-automatic and automatic.
 
2、 Technical parameters:
 
1. Capacity: 5-30ton (adjustable)
 
2. Temperature range: normal temperature ~ 250 ℃
 
3. Temperature accuracy: ± 1 ℃
 
3. Temperature controller: PLC touch screen
 
4. Temperature control mode: PLC touch screen
 
5. Heater: heated by electric heating tube
 
6. Working mode: electric heating. Heating mode: electric heating.       
 
7. Heating time: About 15min from normal temperature to 160 ℃ (adjustable heating rate)
 
8. Timer: PLC display, 0.01s ~ 999min ~ 999hr (adjustable)
 
9. Hot pressing plate: 300 × 300 mm (high hardness steel plate with special treatment)
 
10. Exhaust function: low pressure automatic exhaust, 3 ~ 10 times a minute, adjustable
 
11. Oil pressure system: proportional hydraulic flow closed loop control system, GPY oil pump (made in Japan) drives high-performance electro-hydraulic with high-precision non resistance oil cylinder piston to execute equal rate control mode (stroke height can be set independently) with automatic pressure compensation function, the pressurization time can be preset, the load force is strong, the lifting is stable, automatic pressurization, pressure holding and pressure relief are realized
 
12. Cylinder stroke: Max 300 mm
 
13. Cylinder speed: 11mm / S
14. Pressure gauge: 0 ~ 200kg / sq.cm
15. Volume: (w × D × h) 1400 × 750 × 1460 mm
16. Power supply: 3 ∮, AC220V, 15A
17. Weight: About 350kg
3、 Operation method of testing machine
 
1. First of all, the testing machine is adjusted horizontally by placing the level meter on the machine base of the machine, and the foundation screw is adjusted to be horizontal according to the instructions of the level gauge (adjustment when installing the machine or moving the machine).
 
2. Turn on the main power switch to make the power supply pass through the control panels of the machine.
 
3. Set the test temperature.
 
4. Set the temperature of upper, middle upper, middle lower and lower die respectively according to the style requirements. When the temperature reaches the set temperature, open the cylinder door and place the isolation stainless steel plate and pattern.
 
5. Start the test key to make the hydraulic cylinder pressure up to start the test (do not adjust the pressure and speed of the hydraulic system at will).
 
6. After reaching the set time, the system will reset automatically.
 
7. Observe the pattern and finish the test.
4、 Precautions and maintenance
 
4.1 precautions:
 
4.1.1. The power supply of the monitor and motor is input according to the label.
 
4.1.2. The operator must be familiar with the operation and maintenance methods of the machine and pay attention to its use.
 
4.1.3. The storage environment should be kept clean and not wet.
 
4.1.4. When it is necessary to move, please pay attention to handling, and do not damage the parts.
 
4.1.5. When replacing the fixture, attention should be paid to taking and placing, so as to avoid falling and bumping machine parts.
 
4.1.6. Regularly check whether the drive belt is loose and adjust it.
 
4.1.7. Please apply for inspection and correction regularly to ensure the accuracy.
 
4.2 maintenance items:
 
4.2.1. The surface of the machine part should be wiped regularly to keep it clean.
 
4.2.2. Please wipe the electroplating part with oil to prevent rust and keep it bright.
 
4.2.3. Please add lubricating oil to the power screw and screw parts to ensure the sensitivity of transmission. (the lubricating oil can be mixed with butter and a little oil).
 
4.2.4. Please wipe the panel (control box, i.e. monitor) with dry cloth to prevent water from damaging IC electronic parts.
 
4.2.5. All fixtures and joint accessories should be properly placed, and the anti rust oil should be wiped to prevent rust.
 
Equipment installation requirements
 
1. Installation site
 
If there is strong ventilation and dust around the equipment, there is no room for strong ventilation and equipment maintenance, as shown in the figure below
 
1. External temperature: 27 ℃± 3 ℃ relative humidity: ≤ 85% air pressure: 86kpa ~ 106kpa
 
2. There should be a certain space around the equipment to facilitate maintenance, as shown in the figure on the right
 
A: not less than 10cm B: not less than 60cm C: not less than 60cm
 
2. Power supply conditions
 
1. Power supply: AC220V two wire + protective ground wire
 
Allowable voltage fluctuation range: AC (220 ± 10%) V
 
Allowable frequency fluctuation range: (50 ± 0.5) Hz
 
The grounding resistance of protective ground wire is less than 4 Ω
 
Power supply capacity: the maximum power is about (to be provided separately, but the scheme has not yet come out). It is required to equip the equipment with air or power switch with corresponding capacity at the installation site, and the switch must be used independently for the equipment
 
2. Requirements for storage environment
 
1. When the equipment is not working, the ambient temperature should be kept within 5 ℃ ~ + 30 ℃ (in kind)
technical specifications

model

Gd-518 series 23kn

WBE-9909B

WBE-9909A

Capacity selection

5、10、20、30、50、100、200kN

Three ranges are available as standard

Accuracy class

Class 0.5 for type B / grade 1 for type A

Load parameters

Measurement range of test force

Full scale (2.0% FS)

Indication error of test force

Within ± 0.5% of indication value of model B / within ± 1% of indication value of model a

Test force resolution

The maximum test force of type B is 500000 / that of model a is 200000,

There is no grading in the whole process, and the resolution remains unchanged

Displacement parameters

Displacement indication error

Within ± 0.2% of indication value of model B / within ± 0.5% of indication value of model a

Displacement resolution

0.015 μ m for type B and 0.1 μ m for type A

control

system

ginseng

number

Stress control rate range

Model B 0.005-5% FS / S / a model 0.05-5% FS / S

Accuracy of stress control rate

When the speed of type B is less than 0.05% FS / s, it is within ± 1% of the set value; when the speed is greater than or equal to 0.05% FS / s, it is within ± 0.5% of the set value;

When the speed of model a is less than 0.1% FS / s, it is within ± 2% of the set value; when the speed is greater than or equal to 0.1% FS / s, it is within ± 0.5% of the set value;

Strain control rate range

Model B 0.005-5% FS / S / a model 0.05-5% FS / S

Accuracy of strain control rate

When the speed of type B is less than 0.05% FS / s, it is within ± 1% of the set value; when the speed is greater than or equal to 0.05% FS / s, it is within ± 0.5% of the set value;

When the speed of model a is less than 0.1% FS / s, it is within ± 2% of the set value; when the speed is greater than or equal to 0.1% FS / s, it is within ± 0.5% of the set value;

Displacement control rate range

001 ~ 500mm / min or agreed

0.001 ~ 300 mm / min or agreed

0.001 ~ 300 mm / min or agreed

Accuracy of displacement control rate

B model is within ± 0.2% of the set value / a model is within ± 0.5% of the set value

Relative error of force control rate

Within + 1% of the set value of model B / within + 2% of the set value of model a

Control range of constant stress, constant strain and constant displacement

0.5% ~ 100% FS for model B / 1% ~ 100% FS for model a

Control accuracy of constant stress, constant strain and constant displacement

When FS is less than or equal to 10% of the set value, the set value of FS ≥ 1% is less than or equal to 10%

It is within ± 2% of the set value when the set value of a model is ≥ 10% FS, and within ± 0.5% of the set value when the set value is ≥ 10% FS

main

machine

ginseng

number

Overall dimension (length, width and height)

About 1285 × 800 × 1900mm

Test space without fixture

1000mm (or agreed)

Effective test width

550mm (or agreed)

Power Supply

380V  50Hz,±10%

power

4KW(300KN)

Main engine weight

About 800kg (300KN)

 


 Industry application

 Cooperative customers

 Delivery and after sales

Related products / Related Products

QQ consultation

Online consultation Sincerely provide you with professional answer service

Consultation hotline

0769-22247727
7 * 24-hour service hotline

Focus on wechat

 QR code Scan to add wechat
Back to the top